HUM1000, a large-bore ultrasonic heat meter, measures thermal energy carried by liquids or steam. It gauges fluid velocity via ultrasonic principles and computes heat output based on the temperature differential between the inlet and outlet pipes. Widely applied in district heating networks, industrial manufacturing and energy management systems, HUM1000 delivers accurate energy measurement and facilitates efficient energy consumption control.
· Adopts the ultrasonic measurement principle,, featuring zero mechanical friction and long service life. · Designed for large-caliber pipelines, widely applied in central heating and district cooling systems. · Equipped with communication interfaces to support remote monitoring and data collection. · Powered from a lithium battery. Depending on use and setup, the lifetime is up to 10 years. · Minimal pressure drop reduces pipeline operation energy consumption effectively. · Complete self-diagnosis fault function for convenient daily management.
| Measured Medium | Domestic water (other liquids require customization) and must fill the pipe | ||
| Nominal Diameter | DN50~DN300 | ||
| Qp/Qi | R50/R100 | ||
| Accuracy Class | 2 | ||
| Power Supply | DC3.6V lithium battery | ||
| Operating Pressure | 16bar | ||
| Environment Class | A | ||
| Temperature Difference Measurement Range | 4°C~95°C | ||
| Temperature Difference Range | 2K~75K | ||
| Pressure Loss | △P25 | ||
| Heat Consumption Calculation | Starting from 1K | ||
| Temperature Resolution | 0.01°C | ||
| Electromagnetic Ambient Condition | E1 (optional E2 level) | ||
| Maximum Water Volume Reading (m³) | 999999.99 | ||
| Maximum Heat Reading (Kw·H) | 99999999 | ||
| Battery Life | >10 years | ||
| Temperature Sensor | PT1000 platinum resistor | ||
| Pipe Material | Ductile Iron | ||
| Communication Method | Infrared/M-Bus/RS485/LoRa/LoRaWAN/NB-IoT/Cat1/TTL, etc. | ||
| Protection Class | IP65/IP68 | ||
| Installation Method | Arbitrary angle | ||